With the advent of 40G Ethernet, many enterprise users have begun to take full advantage of current 10G network equipment to upgrade to 40G networks. In other words, this involves the use of 40G switches with QSFP+ ports and existing 10G devices (switches and servers) with SFP+ ports. In this article, Walsun will share three common solutions and teach you how to interconnect the switch 40G QSFP+ port and 10G SFP+ port.
Cable solution: use QSFP+ branch cable
QSFP+ branch cables include QSFP+ to 4*SFP+ DAC passive copper cables,and QSFP+ to 4*SFP+ AOC active optical cables, both of which are connected to a QSFP+ module at the A end and 4SFP+ modules at the B end, of which thepassive copper cablesupports a transmission distance of 7m, and the active optical cable supports a transmission distance of 70m.In addition to the above two types of cables, there is a QSFP+ to 4 LC duplex AOC cable. One end of the cable is QSFP+ and the other end is 4 duplex LC optical fiber patch cords, which can be used when 4 SFP+ optical modules are reserved, thus realizing the conversion of QSFP+ to SFP+.

Walsun’s QSFP+ to 4*SFP+ AOC active optical cable has a built-in 4-channel 850nm VCSEL laser array and a PIN photodetector array, whichsupportsdigital diagnostic monitoring(DDM). Specifically speaking, it can not only comprehensively analyzethe information includingthe detected temperature, voltage, transmitting and receiving optical power, and warning and alarm status of the laser bias current, so as to predict the fault and locate the fault location, thereby shortening the fault repair time and reducing the loss, but also can predict the life of the laserby monitoring the bias current of the laser.

Walsun’s QSFP+ to 4*SFP+ DAC passive copper cable has the advantages of anti-radiation interference and lower power consumption. It is the best solution for data transmission within 7m at low cost.

In the 10G upgrade to 40G network solution, you can use a 40G QSFP+ to 4*SFP+ direct connection cable to directly connect to the switch without purchasing additional optical modules, so that it canhelp you save network costs and simplify the connection process. However, the transmission distance of this connection is limited. Therefore, the DAC or AOC direct-connect optical cable is more suitable for the connection of the switch inside the cabinet or the switch between two adjacent cabinets.
Patch cord scheme: use MPO to transfer 4 duplex LC branch patch cords
The MPO to LC branch patch cordis an OM3 or OM4 multi-mode optical fiber that connects the MPO connector with 8/12 cores at the A end and 4 duplex LC connectors at the B end. When using the MPO to LC branch patch cord scheme, one40G QSFP+ SR4 optical module and four 10G SFP+ SR optical modules need to be reserved at both ends of the switch. When using,wejust insert the MPO connector into the 40G QSFP+ SR4 optical module interface, and then insert the 4 duplex LC connectors into the 4 10G SFP+ SR optical module interfaces.

Conversion module solution: CVR-QSFP-SFP10G conversion module
The solution is to convert 40G ports on the switch to 10G ports through the 40G QSFP+ to 10G SFP+ converter module CVR-QSFP-SFP10G, so as to realize the interconnection of QSFP+ ports and 10G SFP+ ports. The operation method is to insert the 40G converter CVR-QSFP-SFP10G into the QSFP+ port, and then insert the 10G SFP+ optical module. By doing this, you can replace the 40G port with a 10G port

In actual data centers or other high-density cabling applications, network upgrades are a complicated process, and sometimes cross-connections can be considered, but the specific method requires comprehensive consideration of transmission distance, transmission media, network density, and cost factors. Therefore, within the transmission distance of 7m, Walsunrecommends that youcanchoose QSFP+ to 4*SFP+ DAC passive copper cable, which is the most cost-effective in the short-distance transmission scheme; within the transmission distance of 70m, it is recommended that you choose QSFP+ to 4*SFP+ AOC active optical cable. Within the transmission distance of 100m, it is recommended that you choose MPO to 4 duplex LC branch patch cordsto connect the 40G SR4 optical modules and 10G SR optical modules at both ends.
Related Article:
What Are the Different 10G Network Cabling Solutions Available
What Are the Differences Between 25G SFP28 SR and 25G SFP28 LR
How to Apply 16G SFP+ FC Optical Fiber Modules in Fibre Channel Switches
How to Use 25G SFP28 Optical Modules in 5G Fronthaul
How to Decide Between High-Speed Cables and Active Optical Cables for Data Centers